Silicon Labs /SiM3_NRND /SIM3L167_C /LDO_0 /CONTROL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as CONTROL

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0ALDOOVAL0 (LOW)ALDOBSEL 0 (VBAT)ALDOSSEL 0MLDOOVAL0 (LOW)MLDOBSEL 0 (VBAT)MLDOSSEL 0DLDOOVAL0 (LOW)DLDOBSEL 0 (VBAT)DLDOSSEL

MLDOSSEL=VBAT, DLDOSSEL=VBAT, ALDOBSEL=LOW, MLDOBSEL=LOW, DLDOBSEL=LOW, ALDOSSEL=VBAT

Description

Control

Fields

ALDOOVAL

Analog LDO Output Value Select.

ALDOBSEL

Analog LDO Bias Select.

0 (LOW): Select a low bias for the analog LDO.

1 (HIGH): Select a high bias for the analog LDO.

ALDOSSEL

Analog LDO Source Select.

0 (VBAT): Select the VBAT pin as the input voltage to the analog LDO.

1 (DCDC): Select the output of the DC-DC converter as the input voltage to the analog LDO.

MLDOOVAL

Memory LDO Output Value Select.

MLDOBSEL

Memory LDO Bias Select.

0 (LOW): Select a low bias for the memory LDO.

1 (HIGH): Select a high bias for the memory LDO.

MLDOSSEL

Memory LDO Source Select.

0 (VBAT): Select the VBAT pin as the input voltage to the memory LDO.

1 (DCDC): Select the output of the DC-DC converter as the input voltage to the memory LDO.

DLDOOVAL

Digital LDO Output Value Select.

DLDOBSEL

Digital LDO Bias Select.

0 (LOW): Select a low bias for the digital LDO.

1 (HIGH): Select a high bias for the digital LDO.

DLDOSSEL

Digital LDO Source Select.

0 (VBAT): Select the VBAT pin as the input voltage to the digital LDO.

1 (DCDC): Select the output of the DC-DC converter as the input voltage to the digital LDO.

Links

()